为什么我的计算机时间网路同步总是超时
发布网友
发布时间:2022-04-24 00:27
我来回答
共2个回答
热心网友
时间:2023-10-15 12:37
选一个国内的时间服务器。
我现在用的是time.windows.com,电信网络,很快。
网上找一NTP
210.72.145.44 (国家授时中心服务器IP地址)
133.100.11.8 日本 福冈大学
time-a.nist.gov 129.6.15.28 NIST, Gaithersburg, Maryland
time-b.nist.gov 129.6.15.29 NIST, Gaithersburg, Maryland
time-a.timefreq.bldrdoc.gov 132.163.4.101 NIST, Boulder, Colorado
time-b.timefreq.bldrdoc.gov 132.163.4.102 NIST, Boulder, Colorado
time-c.timefreq.bldrdoc.gov 132.163.4.103 NIST, Boulder, Colorado
utcnist.colorado.e 128.138.140.44 University of Colorado, Boulder
time.nist.gov 192.43.244.18 NCAR, Boulder, Colorado
time-nw.nist.gov 131.107.1.10 Microsoft, Redmond, Washington
nist1.symmetricom.com 69.25.96.13 Symmetricom, San Jose, California
nist1-dc.glassey.com 216.200.93.8 Abovenet, Virginia
nist1-ny.glassey.com 208.184.49.9 Abovenet, New York City
nist1-sj.glassey.com 207.126.98.204 Abovenet, San Jose, California
nist1.aol-ca.truetime.com 207.200.81.113 TrueTime, AOL facility, Sunnyvale, California
nist1.aol-va.truetime.com .236.96.53 TrueTime, AOL facility, Virginia
————————————————————————————————————
ntp.sjtu.e.cn 202.120.2.101 (上海交通大学网络中心NTP服务器地址)
s1a.time.e.cn北京邮电大学
s1b.time.e.cn清华大学
s1c.time.e.cn北京大学
s1d.time.e.cn东南大学
s1e.time.e.cn清华大学
s2a.time.e.cn清华大学
s2b.time.e.cn清华大学
s2c.time.e.cn北京邮电大学
s2d.time.e.cn西南地区网络中心
s2e.time.e.cn西北地区网络中心
s2f.time.e.cn东北地区网络中心
s2g.time.e.cn华东南地区网络中心
s2h.time.e.cn四川大学网络管理中心
s2j.time.e.cn大连理工大学网络中心
s2k.time.e.cn CERNET桂林主节点
s2m.time.e.cn 北京大学
刚试了下,国内的超时,特别是教育网的更不行。
132.163.4.101
132.163.4.102
132.163.4.103
这几个都成功了。
热心网友
时间:2023-10-15 12:38
主板电池没电了,没有记忆功能啦,这和部分手机一样,有些手机芯片是有记忆功能的,即使电板拿掉,关机,再次开机时间依旧是准确的,去换个纽扣电池就好了,一般就是这样的,没啥问题~
热心网友
时间:2023-10-15 12:37
选一个国内的时间服务器。
我现在用的是time.windows.com,电信网络,很快。
网上找一NTP
210.72.145.44 (国家授时中心服务器IP地址)
133.100.11.8 日本 福冈大学
time-a.nist.gov 129.6.15.28 NIST, Gaithersburg, Maryland
time-b.nist.gov 129.6.15.29 NIST, Gaithersburg, Maryland
time-a.timefreq.bldrdoc.gov 132.163.4.101 NIST, Boulder, Colorado
time-b.timefreq.bldrdoc.gov 132.163.4.102 NIST, Boulder, Colorado
time-c.timefreq.bldrdoc.gov 132.163.4.103 NIST, Boulder, Colorado
utcnist.colorado.e 128.138.140.44 University of Colorado, Boulder
time.nist.gov 192.43.244.18 NCAR, Boulder, Colorado
time-nw.nist.gov 131.107.1.10 Microsoft, Redmond, Washington
nist1.symmetricom.com 69.25.96.13 Symmetricom, San Jose, California
nist1-dc.glassey.com 216.200.93.8 Abovenet, Virginia
nist1-ny.glassey.com 208.184.49.9 Abovenet, New York City
nist1-sj.glassey.com 207.126.98.204 Abovenet, San Jose, California
nist1.aol-ca.truetime.com 207.200.81.113 TrueTime, AOL facility, Sunnyvale, California
nist1.aol-va.truetime.com .236.96.53 TrueTime, AOL facility, Virginia
————————————————————————————————————
ntp.sjtu.e.cn 202.120.2.101 (上海交通大学网络中心NTP服务器地址)
s1a.time.e.cn北京邮电大学
s1b.time.e.cn清华大学
s1c.time.e.cn北京大学
s1d.time.e.cn东南大学
s1e.time.e.cn清华大学
s2a.time.e.cn清华大学
s2b.time.e.cn清华大学
s2c.time.e.cn北京邮电大学
s2d.time.e.cn西南地区网络中心
s2e.time.e.cn西北地区网络中心
s2f.time.e.cn东北地区网络中心
s2g.time.e.cn华东南地区网络中心
s2h.time.e.cn四川大学网络管理中心
s2j.time.e.cn大连理工大学网络中心
s2k.time.e.cn CERNET桂林主节点
s2m.time.e.cn 北京大学
刚试了下,国内的超时,特别是教育网的更不行。
132.163.4.101
132.163.4.102
132.163.4.103
这几个都成功了。
热心网友
时间:2023-10-15 12:38
主板电池没电了,没有记忆功能啦,这和部分手机一样,有些手机芯片是有记忆功能的,即使电板拿掉,关机,再次开机时间依旧是准确的,去换个纽扣电池就好了,一般就是这样的,没啥问题~